School Zone Timers and Annual Event Timer, 365 Day 24 Hr. Timer, Timers 365 Day 24 Hr 4 Channel Annual Event IQTimer is an extremely versatile 24 Hour 365 Day Event Timer designed to support a wide range of applications.'
OkSolar If you can dream it, We can energize it!

Help

Click Here! To Search for prices and Order Online our products database

Get A Quote

Order Online
  -Request Pricing
  -View Our Clients
 How we Work
 How to Get a Quotation

  -Contact Us
  -View My Invoice

 


  -Export Information
  -¡Hablamos Español!
  -Buy Online

Aviation Products
  -Airfield Lighting
  -Airfield Accessories
  -Airport Your Speed Traffic Signs
  -Airport 24 Hour Flashing Beacons
  -Airport 24 Hour Flashing Beacon
  -Airport Lighting Controls
  -Airport Video Surveillance
  -Approach Lighting Systems
  -Airport Elevated Runway Lights
  -Crane Obstruction Lights
  -Elevated Runway Guard Lights
  -Obstruction Lighting
  -Runway & Taxiway Elevated Lights
  -Runway & Taxiway Inserts Lights
  -Solar Aviation Lights
  -Solar Beacons Lights
  -Solar Crane Lights
  -Solar Helipad Lights
  -Solar Obstruction Lights
  -Solar Perimeter Lights
  -Solar RunWay Lights
  -Solar RunWay EDGE Lighting
  -Solar TaxiWay Lights
  -Solar TAXIWAY Lighting
  -Solar Threshold Lights
  -Solar PAPI Lights
  -Solar Tower Lights
  -Solar Wind Cones
  -Solar Airport UPS Backup Energy
Automation
  -Data Acquisition
  -Motion Sensors
  -SCADA
  -Software
  -Solar Power Generator
Catalog
  -Catalogs in PDF
Communications
  -Wireless Airfield Light Control
  -Wireless Control
  -Wireless Lighting Control
Components
  -Batteries
  -Enclosures
  -Enclosures Air Conditioners
  -Enclosures Thermal Management
Computers
  -Apps
  -Coud Services
  -Computer Solar Backups
  -Commercial Building Automation
  -Computer Solar Chargers
Electronics
  -Battery Chargers
  -DC to DC Converters
  -Din Rail Power Supply
  -Electrical Vehicles
  -Electrical Vehicle Charging
  -OEM
  -Power Supplies
  -Timers
Enclosures
  -Battery Enclosure
  -LTE enclosure 4G Enclosure
  -Outdoor enclosures Single Bay
  -Outdoor Enclosure Double Bay
  -Outdoor enclosure Triple Bay
  -Traffic enclosures
Energy Solutions
  -Battery Backup Storage
  -Energy Storage
  -Fuel Cells
  -Hospital Emergency
  -Hospital Fuel Cells UPS
  -Hospital Signals
  -Landfills Green Energy Generator
  -Modular Power Storage
  -Pipeline Oil and Gas
  -Portable Solar Power Generator
  -Solar Powered SCADA
  -Security and Surveillance
  -Solar EV Charge Station
  -Solar Trailers
  -Solar Trees
  -Telecom Power Supplies
  -Traffic Management
Government
  -Foldable Solar Battery Charger
  -Fuel Cells Military
  -GSA Government
  -Homeland Security
  -Military Bases Your Speed Signs
  -Military Solar Gate Openers
  -Military Secure Fence Lighting
  -Military Video Surveillance
  -Portable Military Solar Power
Hospital
  -Hospital Emergency Back-Up Power
  -Hospital Signals
  -Hospital Solar 24 Flashing Beacons
  -Hospital Solar Parking Lot Lighting
  -Hospital Solar Powered Speed Radar
  -Hospital Solar Video Surveillance
  -Medical Grade UPS
  -Medical Grade Fuel Cells Backup
  -Inverters Ambulance EMS
  -Vaccine Refrigerators Solar
Lighting
  -Arms
  -Billboards LED Lighting
  -Bridge Solar LED Lighting
  -Bus Stop Shelter Solar Light
  -Bullet Proof Solar LED Lights
  -Explosion Proof Lights
  -Explosion Proof Rotating Lights
  -LED Street Lights
  -Perimeter Security Lighting
  -Poles
  -Solar LED Lighting
  -Solar Street Lighting
  -Solar LED Street Lighting
  -Solar Parking-Lot Lighting
  -Solar Light Tower
  -Solar Security Lighting
  -School Parking lot Lighting
  -Solar Powered Parking Lot Light
  -Tunnel Lighting
Marine
  -Marine Navigation Lights
  -Port Entry Lights
  -Solar Marine Lighting
  -Solar Marine Navegation Lights
  -Marine Navigation Lights
Military Sytems
  -Military Bases Solar Lighting
  -Military Energy Storage
  -Military Traffic Safety
  -Military Video Surveillance
  -Military Video Surveillance Solar
  -Military Solar Light Tower
  -Military Bases Your Speed Signs
  -Military Portable Solar Power
  -Military Solar Enery Trailer
Obstruction Lights
  -Obstruction Lights FAA
  -Obstruction Lights ICAO
  -Obstruction Lighting
  -Solar Obstruction Lighting
  -Solar Obstruction Lighting FAA
  -Solar Obstruction Lighting ICAO
Power Sytems
  -Battery Chargers
  -DC to DC Converters
  -DC to DC Converters Din Rail
  -Din Rail Uninterruptible Power Supply
  -Inverters Accessories
  -Inverters Battery Based Off Grid
  -Inverters Grid-Tied
Projects
  -Battery Storage Smart Grid
  -Commercial- Industrial
  -Military Modular Energy Storage
  -Mobile Solar Power
  -Electrical Vehicle Charging Station
Security
  -Ballistic Protection
  -Cameras
  -Cameras Enclosures
  -Defense And Security Solutions
  -Gate Openers
  -Gate Openers Solar Powered
  -Industrial Video Surveillance
  -Infra Red Illuminators
  -Metal Weapons Detectors
  -Radar Your Speed Sign
  -Solar-Powered Security Lights
Solar Energy Components
  -Charge Controllers
  -Inverters Accessories
  -Inverters Battery Based Off Grid
  -Inverters Grid-Tied
  -Portable Battery Charger
  -Solar Modules
  -Solar Modules Ballistic Protection
  -Mounting Structures
Solar Systems
  -Cathodic Protection
  -Disaster Relief Vehicle
  -Commercial Solar Power
  -Home Solar Power System Grid Tie
  -Home Solar Power System Off Grid
  -Portable Solar Generator
  -Remote Solar Power Supply AC
  -Remote Solar Power Supply DC
  -Solar Powered Parking Lots
Traffic
  -Accessories
  -Battery Backup
  -24/7 Traffic Flashing Beacons
  -LED Traffic Signals
  -Portable Traffic Signals
  -Railroad
  -Railroad Crossing Signals Backup
  -Remote Controlled Signals
  -Solar Powered Traffic Lights
  -Solar Powered Your Speed Signs
  -Solar School Zone Flashing Beacons
  -Solar School Parking Lot Lighting
  -Solar Traffic Lights
  -Traffic Controls
  -Traffic
  -Traffic 24 Hour Solar Flashing Beacon
  -Traffic Solar School Zone Beacons
  -Traffic Your Speed
  -Traffic Parts
  -Traffic Lights
  -Traffic Signal Battery Backup
  -Your Speed Signs Solar Powered
UPS Backup Systems
  -UPS Airport Generators
  -Base Station for Moville Networks
  -UPS Data Center Facilities
  -UPS Emergency Generators
  -UPS Hospital Generators
  -UPS Traffic Generators
  -UPS Fuel Cell Generators
Visual Signals
  -Explosion Proof Rotating Beacons
  -Marine Solar Powered Beacons
  -Solar Marine & Dock Lighting
  -Rotating Beacons
  -Solar Powered Beacons
Water Treatment
  -Solar Powered for Water Treatment
  -Solar Water Pumps Accessories
  -Solar Powered Water Pumps
  -Video Surveillance for Water Treatment Plants
  -Water Pumps
Wind Generators
  -Wind Turbines Accessories
  -Wind Turbines
  -Wind Turbine Obstruction Lighting
  -Wind Turbine Lighting



  -Become Partner
  -Export How To
  -¡Hablamos Español!
  Our Blog | News | Our App


Credit Card Transactions Secured by!

Click Here for Catalog in PDF format!
Click to Access our Catalog in PDF


Browse our product catalog, submit requests for quotation and stay up to date with product news, specials and environmental news.


Our Blog is managed with Milk-App.com A Tumblr Client for the Mac

A Tumblr Client for the Mac, Everything you love about Tumblr, from the comfort of your desktop.



Bellebnb Hotel Cloud Booking Management.
Booking Engine
Front Desk
Payment Gateway
Channel Management
Hotel Concierge App

Bellebnb Hotel Cloud Booking Management
Hotel Buchung Motor
Cloud Buchung Engine
Motor de Reservas
Hotel Booking Engine
Motore di Prenotazione



IQLED.com
IQAirport.com
IQTraffiControl.com
IQSolarLighting.com
IQUPS.com


© - OkSolar.com ()

- v7.77

Tatami Software

 

 
Timers 365 Day 24 Hr 4 Channel Annual Event IQTimer is an extremely versatile 24 Hour 365 Day Event Timer designed to support a wide range of applications. School Zone Timers and Annual Event Timer, 365 Day 24 Hr. Timer
Pedestrian Countdown Timers: Do Drivers Use Them to Increase

365 Day 24 Hr 4 Channel Annual Event Timer

Overview
Model IQTIMER is an extremely versatile 24 Hour 365 Day Event Timer designed to support a wide range of applications.

Features/Specifications
• 12 to 24 volts AC or DC operation
• Standby current: 20mA with relays off combined with 40mA for each
relay on.
• Four (4) Form “C” relay contacts are rated 10 amp @120VAC/28VDC.
• EE Prom memory protects against loss of programming due to
power failure.
• Accurate crystal controlled clock (DC operation).
• Momentary and/or Latching Events.
• 254 individually programmed daily/weekly events.
• Block programming capacity can accommodate a total of 1778 events
per week.
• 254 programmable Holiday events.
• “First man in” option.
• Alphanumeric LCD display simplifies programming.
• Standard or Daylight Savings Time settings.
• Automatic compensation for leap year.
• Each relay operates independently.
• Built-in charger for 12VDC sealed lead acid or gel type batteries
(Max charge current 300mA).
• Lithium battery backup maintains clock.
• User friendly keyboard programming.

School Zone Timers and Annual Event Timer, 365 Day 24 Hr. Timer

Timers 365 Day 24 Hr 4 Channel Annual Event IQTimer is an extremely versatile 24 Hour 365 Day Event Timer designed to support a wide range of applications.

12" RED LED BALL FLANGE MOUNT8" RED LED BALL FLANGE MOUNT

12" RED LED BALL SCREWBASE
8" RED LED BALL SCREWBASE
 12" AMBER LED BALL SCREWBASE8" AMBER LED BALL SCREWBASE
12" AMBER LED BALL FLANGE MOUNT
8" AMBER LED BALL FLANGE MOUNT
 12" Blue-green LED BALL SCREWBASE8" Blue-green LED BALL SCREWBASE
12" Blue-green LED BALL FLANGE MOUNT
8" Blue-green LED BALL FLANGE MOUNT
 12" RED LED ARROW SCREWBASE
12" RED LED ARROW FLANGE MOUNT
 12" YELLOW LED ARROW SCREWBASE
12" YELLOW LED ARROW FLANGE MOUNT
12" Blue-green LED ARROW SCREWBASE
12" Blue-green LED ARROW FLANGE MOUNT

 

for this Green Energy Efficient and Safe Solar LED Park Lighting

for this Green Energy Efficient and Safe Solar LED Park Lighting  for this Green Energy Efficient and Safe Solar LED Park Lighting for this Green Energy Efficient and Safe Solar LED Park Lighting 

Custom Solutions for Solar LED Lighting for National Parks LED Solar LED Streetlight in Rome, Italy Green ilumination combination of solar wind

 

 

Custom Solutions for LED Solar LED Streetlight in Rome, Italy Green ilumination combination of solar wind and fuel cells

 

Contact US today!

ABC Technical Information on OkSolar Systems


Installations must me made by licensed technicians.

Technical Assistance or Advice

E-mail is the preferred method of communication and is addressed within 24 hours, 7 days a week.
Please Allow 24-48 Hours for specific technical advise.


Any technical assistance or advice offered by Seller in regard to the use of any Product or provided in connection with Buyer's purchases is given free of charge and only as an accommodation to Buyer. Seller shall have no obligation to provide any technical assistance or advice to Buyer and if any such assistance or advice is provided, such fact will not obligate Seller to provide any further or additional assistance or advice. Seller shall not be held liable for the content or Buyer's use of such technical assistance or advice nor shall any statement made by any of Seller's representatives in connection with the Products or Services constitute a representation or warranty, express or implied.


Installations must me made by licensed technicians.

OkSolar.com is not responsible for any typographical errors. Neither OkSolar.com nor GeneralCommunications.com, corp. is not responsible or liable for errors in installations. We offer industry-standard installations recommendations guide lines; proper installation is the responsibility of the installers.

IMPORTANT NOTICE
The installer assumes full responsibility for the proper application and safe installation of the units in accordance with these instructions, the National Electric Code, and all other state and local codes and practices. OKSOLAR accepts no responsibility for damages to property nor injury to personnel for the improper use of this product nor its failure under any circumstances. OKSOLAR warranty is limited to the replacement of the defective unit only if the failure is the result of a manufacturing defect.

Limitation of Liability
UNDER NO CIRCUMSTANCES WILL OkSolar.com OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE, INTERRUPTION OF BUSINESS, LOST PROFITS, LOST DATA, OR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, EVEN IF OkSolar.com OR ITS AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you. Neither OkSolar.com nor its affiliates or suppliers will be held liable or responsible for any damage or loss to any items or products connected to, powered by or otherwise attached to the Product. The total cumulative liability to Customer, from all causes of action and all theories of liability, will be limited to and will not exceed the purchase price of the Product paid by Customer. This warranty gives the Customer specific legal rights and the Customer may also have other legal rights that vary from state to state.


Communications products: Please be aware that the wireless portion of the system must be handled with care and must be installed by an installer with some notion of radio devices. We attach the radio specifications so that the installer will be able to make any necessary modification to the radios.

Technical Support will be addressed only by email check our contact information
We offer design assistance on hourly basis minimum 3 hours Contact Us for Pricing

Determining the Correct System:

To determine if IQUPS Power system will meet your solar power requirements, first choose what DC voltage your system will operate on, then calculate the Total Equipment Load in Amp-hours per Day. Next, looking at the map of the U.S., determine your Solar Resource. Then, using the selection matrix on the page, choose the appropriate system.

 

We offer design assistance on hourly basis minimum 3 hours contact you sales rep.

This information applies to all systems : Allow the system to charge its batteries four to seven days of full sunlight before switching on the Inverter for first time or after a long period of storage. Very Important!


 



 

 

Graphic Installations Catalog Click on Pictures for technical information

Solar Trees AC, Daily out Put. Pure Sine wave utility grade electricity

Solar Tree

TSPDC Transportable (Trailer-Modular Power Storage)

Modular Energy Storage 16KWh Battery Storage, Large Scale Battery Storage new modular design Plug and Play IQUPS Technology that lets Clients like Hospitals, Airport, Industries, and Utilities scale up as is needed.

Modular Energy Storage 16KWh Battery Storage, Large Scale Battery Storage new modular design Plug and Play IQUPS Technology that lets Clients like Hospitals, Airport, Industries, and Utilities scale up as is needed.

Electric Vehicle Charging Station Solar Powered

Electric Vehicle Charging Station Solar Powered

OkSolar.com High Reliable Systems



Traffic Concrete Pedestal Installation

solar powered school beacon

 


Phoenix Contact Installations

 


OkSolar High IQ Simple Connections line of Charge Controllers Microproccessor



Connections are simple follow the pictures
Connect slots 4 and 3 (SOLAR) to solar panels.
Connect slots 1 and 2 (BATTERY) to the battery.
Connect slots 5 and 6 (LOAD) to the lamp.

 



Batteries Technical information:

-Batteries and Solar Modules Diagram of Connections
-Batteries Instructions
-Buried Batteries Systems
-Video of Battery Connections
-Video Battery Serial Connections
-Video Battery Parallel (Serial + Parallel)


Solar Side Pole Mounts - STANDARD-IN-PV-MOUNTING-STRUCTURES.pdf - How to setup Structure for a Solar Module

 

 

 

 

 

Solar Side Pole Mounts

 

 



 


Solar Module Wiring

-Angles of Orientation
-World Daily Solar Insolation Map.
-Solar Modules Technical Information
-How to install a solar panels
-Solar Modules Wire Connectors
-Daily Solar Radiation

Solar Module Orientation If your site is located in the northern hemisphere, face the solar module true south. Similarly, if your site is located in the southern hemisphere, face the solar module true north.

PV Installation

World Map of Solar Radiation


Solar Modules interconnects

Click Here for more Information

 


Solar LED Combiner box

Solar LED Street Lighting installation Manual

 


Enclosures: Installations


Click Here for more Information
Pole Mounting
Enclosures Mounting Instructions

Enclosures Buried Batteries for LED Solar Systems (7 Inches Minimum Gravel Base.)
Customers have poured concrete boxes into the ground and then placed a OkSolar Box inside the concrete box. Air ventilation provisions and drain system on the bottom  (to be addressed by the installer according to the particular application) are recommended for these types of installations.
Foundation in Figure is given as only a general guide. The contractor has the responsibility to determine the dimensions and type of foundation demanded by the soil conditions at the installation site. If you are burying them to keep the batteries cool then you won't need the insulation. However, if they are burying them to keep them from view then I would suggest using the insulation.


Nuts and Bolts of Grounding


Traffic systems

school speed limits


Traffic Flashers:

Polycarbonate Signals Specs Click on picture

-Traffic Aluminum Pole installation
-Traffic Concrete pedestal installation

-Traffic Installations Parts

Sign installations


TSPDC Transportable (Trailer-Modular Power Storage)

1.    After Towing, Secure TSPDC3.5 Trailer by:

a.    Install Trailer Double Locking Jack Stands.

b.    Position the 2 Tires Stoppers.

c.    Position the 2 cones. 

 

2.    Switch ON the Solar Array.

a.    Switch ON PV DC Breakers.

b.    Switch ON Battery Bank.

c.    Unit will start charging independently of the solar array’s position.

d.    Allow the system to charge its batteries four to seven days of full sunlight before switching on the Inverter for first time or after a long period of storage. Very Important!

 

3.    To maximize the Solar Array output by position the solar array in an angle.

a.    Unlock the solar array by removing the leg pins on the top and side facets (four pins total).

b.    Switch ON the Actuator.

c.    Use Pendant Up-Down to adjust inclination of the solar array. Warning: never raise the actuator when the pins are in place on the top facet of the array. Doing so will result in damaging the panels and actuator.

d.    For long stationary periods or in windy conditions, use the locking pins to secure the solar array on the top facet. Use the actuator to lift the panels to position and insert the pins in each leg, then lower the actuator so that the weight is supported by the locking pins.

 

 

4.    Switch on Inverter AC

a.    ON AC Breakers internals and externals.

b.    Connect AC Loads.

Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS!


This manual contains important safety instructions for the TSPDC Transportable. Read all instructions and cautionary markings on the TSPDC Transportable and on any accessories or additional equipment included in the installation. Failure to adhere to these instructions could result in severe shock or possible electrocution. Exercise extreme caution at all times to prevent accidents.


Solar Array: we recommend fold solar array down in winds over 75mph.

Batteries initial:  Allow the system to charge batteries 4-7 days of full sun before Staring the Inverter.


Grounding: System grounding is the responsibility of the operator or installer.


Grounding requirements may vary by location and or Country depending on the local electric code.
Note: OkSolar.com/GeneralCommunications.com Corp. cannot be responsible for system failure, damages, or injury resulting from improper installation or operation of their products.

TMSPDC Transportable Modular Trailer Customer Operation PDF file

TMSPDC Transportable Modular Trailer Customer Inverter Operation PDF file

 



Area Lighting Poles

All OkSolar poles are designed for ground mounting. Local soil conditions determine the type of foundation required for each pole.

To select a pole, first add the weights and EPA's of the mounting brackets and luminaires to get the combined load per pole. The wind speed is determined by local conditions. The mounting height can be determined by the luminarie manufacturer's specifications. Choose the wind speed category, then the column that exceeds the combined load in weight. Move down the column to the desired weight, then to the first pole that exceeds the combined load EPA. This should be your best value. Remember the pole capacity must exceed the combined load in both weight and EPA.

The pole capacity chart has been calculated with mounting at ground level and 1.3 gust factor included. No provisions have been made for banners, pendants, signs, flags, overhead wiring or other items that might be fastened to the pole.

Local soil conditions determine the type of foundation required for each pole. foundation in Figure is given as only a general guide. The contractor has the responsibility to determine the dimensions and type of foundation demanded by the soil conditions at the installation site.
The capacities shown are based on a 24" off center load. This is usually the most conservative configuration. We have extensive charts for other wind, weight and luminaire mountings. If we know your application, we can provide you with the most economical pole.

Poles Spaicing



Poles wind Load

Poles Wind Load ISOTACH WIND MAP 50 YEAR MEAN RECURRENCE ISOTACH WIND MAP

 

Solar Powered LED Street Light 160400


Bullet Proof Lighting



Bullet Proof Solar Lighting

How to install a Bullet Proof LED Lighting Protection
Applications of bullet-Proof Installations lighting, vandalism, shields, shield, vandal, bullet-proof, bulletproof, protection, protect, resistant, safety, polycarbonate, Torsion Flex, Aero Thermic, thermo, pistol, guard, proof, shoot, shot out, lights, light, street, roadway, area, shoebox, flood, wallpack, wallmount, post-top

 

Lighting information:

A lumen (lm) is the unit of measurement for the amount of light emitted by a light source. A 60-watt light bulb emits 730 lm, while a 50-watt halogen lamp has an output of approximately 900 lm.

What does "Candela", "Lumen", etc. mean?
Lighting Principles and Terms.
Solar LED Color Chart
What is Color Temperature?

 


Communications Radio Installations

Communications Radio Installations

 


How to install a Security PTZ Cameras.


Crane Obstruction Warning Light FAA Obstruction Lights Configurations


Electronics LOW Pressure Ballast

For the Ballast to Correctly Start the Lamp, the Lamp must be positioned within one inch of a grounded metal Surface. Lamp Requeire about 10-16 minutes to reach maximun output

Ballast

Testing Low Pressure Ballast: here are a couple things to consider when testing the ballast without the lamp.

-The ballast should still draw a little current from the input voltage source even without the lamp. The 12 VDC model will draw about 0.35 A and the 24 VDC model about 0.20 A.

-The output voltage can also be checked but you must have a high voltage and high frequency meter. If not, your meter could be damaged. The output voltage of the 12 V model is about 360 Vrms @ 45 kHz. The 24 V ballast will be about 500 Vrms @ 35 kHz.

-If the ballast fails, it generally should not cause damage to the lamp.Wiring connections the LPS40B

-Ballast Installation



Solar Powered Beacons

Solar Powered BeaconsSolar Powered Beacons  Solar Powered BeaconsSolar Powered BeaconsSolar Powered Beacons Solar Powered Beacons

Solar Powered Obstruction Lighting US Department of Transportation

 



Wind Cones, FAA Wind Cone Solar Powered

Wind coneWind coneWind coneWind coneWind cone

Wind cone

Wind cone

Wind cone

Wind cone



 

Timers

TimerTimer 365 Day 24 Hr 4 Channel Annual Event Timer365 Day 24 Hr 4 Channel Annual Event Timer

Programing instructions in PDF
365 Day 24 Hr 4 Channel Annual Event Timer
Additional instructions on keypad installation


 


Calculations

-Voltage Drop Calculation
-Metric Voltage Drop Calculation
-Power Calculation
-Battery Power Calculation

Energy Management

At 1kVA output 3.4kVA runtime for each battery configuration is as follows:
• 12KWh – 12hours

At 2kVA output 3.4kVA runtime for each battery configuration is as follows:
• 12KWh – 5 hours

 


As a "rules of thumb" amps horsepower rating estimated

115 Volts motor - single-phase : 14 amps/hp
230 Volts motor - single-phase : 7 amps/hp
230 Volts motor - 3-phase : 2.5 amps/hp
460 Volts motor - 3-phase : 1.25 amps/hp

Single-Phase Motors - HP and Full-Load Currents

Three-Phase Motors - HP and Full-Load Currents

 

 

 


Solar Powered DC and AC units diagram

 

Scada Enclosure Mounting


 

 

 


 

 


 


 


 




 


 

 





 



Solar water pumps Estimated Water Production from SQFlex Pump

Solar water pumps Estimated Water Production from SQFlex Pump


 

** 6kWh/day of power generation
Four 300-Watt Solar Panel
300 watts x 4 = 1200 Watts/hour X 5 Hours = 6,000 Watts Daily

*16 (6 V) 400 amp-hour sealed AGM batteries
=24 Volts x 4 Banks x 400 Amps = 38.400 Watts
38.4 kWh battery storage capacity at 24 Volts


 

 

 

 

 

 

Click Here for Complete Installation Instructions of School Warning Signals, 24 hours warning Flashers, Road way warning signals, pedestrian crossing, railroad warning, ice on bridge warning, low water crossing,  speed awareness displaysClick Here for Complete Installation Instructions of School Warning Signals, 24 hours warning Flashers, Road way warning signals, pedestrian crossing, railroad warning, ice on bridge warning, low water crossing,  speed awareness displaysClick Here for Complete Installation Instructions of School Warning Signals, 24 hours warning Flashers, Road way warning signals, pedestrian crossing, railroad warning, ice on bridge warning, low water crossing,  speed awareness displays

 

Solar Powered Traffic LightsSolar Powered Traffic LightsSolar Powered Traffic LightsSolar Powered Traffic LightsTraffic Lights 120VAC or 230 VAC

 

Ballistic Protection: Stop this from happening at once! Item#54780

  • Ballistic Protection - Bullet Proof Shields

  • This patented* shield incorporates leading edge technology to provide maximum ballistics resistance.

  • The shield is primarily constructed of dual layer polycarbonate sheets which are UV stabilized.

  • Designed to stop small arms fire .22 to .44 caliber

Click Here to Get a Quote!

Click Here to Get a Quote!


Solar Powered Solar Powered Railroad-Highway Grade Crossing United States Department of Transportation - Federal Highway Administration







 

OkSolar.com Serving The Industry Since 1988.
All rights reserved. All trademarks or product names mentioned herein are the property and responsibility of their respective owners.
Credit Pictures provided by PIX along with DOE/NREL

V7.17


Sample Ready to ship unit

 

OkSolar.com Serving The Electronics Industry Since 1988.
  All rights reserved. All trademarks or product names mentioned herein are the property and responsibility  of their respective owners. 
Credit Pictures provided by 

Email to Us | Export  |Terms & Conditions | Powered By GeneralCommunications.com